In a complex power grid environment, improving the line selection accuracy of the small current grounding line selection device is a challenge, but the accuracy of this process can be significantly improved by adopting advanced technologies and design methods. The core of this device is that it can effectively handle various complex situations caused by single-phase grounding faults in the power system and accurately identify the specific line where the fault occurs.

First, the fully embedded structure provides a solid hardware foundation for the small current grounding line selection device. Compared with traditional devices, this structure not only improves the integration of the system, but also enhances the anti-interference ability, enabling the device to operate stably in a complex electromagnetic environment. In addition, the highly integrated design reduces the number of external connection points and reduces the risk of misjudgment caused by wiring problems. Therefore, in a complex power grid environment, the fully embedded structure ensures that the line selection device has higher reliability and stability, thus laying the foundation for accurate line selection.

Secondly, the comprehensive line selection algorithm combining steady-state quantities and transient quantities is one of the key technologies to improve the accuracy of line selection. In actual power grid operation, different types of faults will produce different electrical characteristics. Steady-state quantity analysis focuses on long-term stable changes in electrical parameters, while transient quantity focuses on rapid fluctuations in a short period of time. Combining the two, the power grid state can be comprehensively evaluated from multiple angles, capturing more information about the fault location. This method can adapt to various complex fault scenarios, whether it is slowly developing insulation degradation or an instantaneous short-circuit accident, it can be accurately detected and located.

The application of fuzzy theory further improves the intelligence level of line selection devices. In the face of uncertainty and variability in the power grid, fuzzy theory provides an effective way to process information. By fuzzy information fusion of the results of multiple fault line selection methods, each line will obtain a comprehensive fault measurement coefficient, that is, the line fault credibility coefficient. This method not only takes into account the possible limitations of a single line selection method, but also takes advantage of the complementary advantages of each method. It allows the device to dynamically adjust the judgment criteria according to the actual situation, and make reasonable decisions even when the information is incomplete or there is noise. Therefore, fuzzy information fusion technology greatly improves the accuracy of line selection, especially under complex power grid conditions.

In addition, weak signal processing is also an important part of improving line selection accuracy. In some cases, especially when the fault occurs far away from the substation, the generated signal is very weak and difficult to be captured by conventional means. To this end, the small current grounding line selection device uses special signal amplification and filtering technology to enhance the sensitivity of these weak signals. At the same time, the optimized algorithm design ensures that even when the signal strength is low, useful information can be accurately extracted to help determine the fault location.

In order to cope with special working conditions, such as extreme events such as lightning strikes or short circuits, the line selection device must also have a fast response mechanism. This means that the device must not only be able to monitor the power grid status in real time, but also detect and handle abnormal situations in the first place. Through the built-in efficient algorithm and intelligent control system, the line selection device can complete the entire process from fault detection to accurate positioning in a very short time, minimizing power outage time and losses.

Finally, considering the growing complexity and intelligent needs of modern power grids, line selection devices need to continue to evolve and improve. With the large-scale access of new energy and the popularization of distributed power generation systems, the power grid structure has become more diverse and dynamic. This requires the line selection device to have stronger adaptability and scalability so that it can support more application scenarios and service needs in the future.

In summary, in a complex power grid environment, the small current grounding line selection device can significantly improve the accuracy of line selection by adopting a highly reliable fully embedded structure, a comprehensive line selection algorithm combining steady-state and transient quantities, fuzzy information fusion technology, and special measures for weak signal processing. These technologies work together to ensure that the device can provide strong support for the safe and stable operation of the power grid, whether in normal operation or in the face of sudden failures.
×